Your Region:
Call Toll Free: 1 (888) 755-7718 | sales@upsbatterycenter.ca

Peak Energy PK12V2APC 12V 2Ah Battery

Peak Energy PK12V2APC 12V 2Ah Battery
High Performance
Brand New Fresh Stock
1 Year Warranty Included
Availability: In stock
CAD $32.99

Description

Details

SPECIFICATIONS 
Model DescriptionPeak Energy PK12V2APC rechargeable sealed lead acid (VRLA) battery
Nominal Voltage12 Volt
Capacity (@ 20hr-rate)2 Ah
Weight1.656 Lbs (0.751 kg)
Case MaterialA.B.S. (UL94-HB)
TerminalFaston Type 187 (F1) & Pressure Contact
Maximum Short Duration Discharge Current30 Ah (5 Seconds or Less);
20Ah (10 Seconds or Less);
12 Ah (60 Seconds or Less)
Internal Resistance45 mOhm (Fully Charged Battery) (Approx)
Energy Density (@ 20hr-rate)1.46 watt-hours/cubic inch (88.89 watt-hours/litre)
Specific Energy (@ 20hr-rate)14.5 watt-hours/pound (31.96 watt-hours/kg)
Operating Temperature RangeDischarge: -4°F (-20°C)  ~ 122°F (50°C); 
Recharge: 32°F (0°C)  ~ 104°F (40°C); 
Storage:-20°F (-4°C)  ~  40°F (104°C)
Self Discharge RateAbout 3 %/Month @ 68 ~ 77°F (20 ~ 25°C)


DIMENSIONS

 
Length5.91 in. (150 mm)
Width0.79 in. (20 mm)
Case Height3.54 in. (90 mm)
Terminal Height3.54 in. (90 mm)

 

                                  

CHARTS

 
 
 
Constant Current Discharge Characteristics at 73.4°F (23°C)

Discharge Time

Discharge Amperes

Capacity in Ah’s

Final Voltage

Discharge

C-Rate

20 hr

0.10

2.00

10.50

0.05

10 hr

0.18

1.80

10.50

0.09

5 hr

0.34

1.70

10.20

0.17

4 hr

0.40

1.60

10.20

0.20

60 min

1.20

1.20

9.48

0.6

31 min

2.00

1.04

9.00

1.0

7 min

6.00

0.70

6.00

3.0

 

Recharge Method: Connect battery to a Current Limited, Constant Voltage Source.

Limit the initial recharge current to 500 mA or less.

To promote satisfactory performance in Cyclic applications, a minimum recharge current of 200 mA is recommended.

Employ  Charge Voltage Temperature Compensation when battery  temperature is less than 50°F (10°C) 0r greater than 86°F (30°C), Use the Recommended voltage and normalize to 77°F (25°C).

The use of compensation through the whole temperature range is not generally necessary, but doing so may optimize service life.

If the Recommended recharge voltage is used, no Temperature Compensation is required within the range of 50 ~ 86°F (10 ~ 30°C)

Cyclic Application Recharge Voltage (77°F / 25°C)

Minimum

Recommended

Maximum

 


Volts D.C.

Per Cell

14.40

14.55

14.70

2.40

2.425

2.45

Temperature Coefficient: -2.8mV/°F/Cell (-5mV/°C/Cell)

Standby Application Recharge Voltage (77°F/25°C)

Minimum

Recommended

Maximum

 


Volts D.C.

Per Cell

13.50

13.65

13.80

2.25

2.275

2.30

Temperature Coefficient: -1.7mV/°F/Cell (-3mV/°C/Cell)