Call Toll Free: 1 (888) 755-7718 sales@upsbatterycenter.ca

12V 2.6Ah Sealed Lead Acid Battery (F1 Terminal)

12V 2.6Ah TLV1226 F1 Sealed Lead Acid Battery
High Performance
Brand New Fresh Stock
1 Year Warranty Included

Availability: In stock

CAD $28.99

Shipping Information

  •   This item is in stock and ships within 1 business day
  •   We will gladly accept returns for any reason within 30 days of receipt of delivery
  •   Continental USA & Canada

Description

Details

Features of the TLV1226 Battery with F1 Terminals
 • Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance
   or water  adding.

 • Not restricted for air transport-complies with IATA/ICAO Special Provision A67.
 • UL-recognized component.
 • Can be mounted in any orientation.
 • Computer designed lead, calcium tin alloy grid for high power density.
 • Long service life, float or cyclic applications.
 • Maintenance-free operation.
 • Low self discharge.
 
Common Use & Applications:
 • UPS Standby Power Applications
 • Data Centers
 • Emergency 911 Centers
 • Hospitals & Medical Applications
 • Military Power Equipment
 • Emergency Lighting
 • Fire Detection and Alarm Devices
 
Product Specifications

 
Terminal: F1
Length 178mm (7.01 inch)
Width 35mm (1.38 inch)
Height 61mm (2.40 inch)
Total Height 67mm (2.64 inch)
Approx. Weight (kg / lbs) 1.0 (2.2)
   
Performance Characteristics

 
Nominal Voltage 12V
Nominal Capacity 77°F(25°C)  
   20 hour rate (0.13A, 10.5V) 2.6Ah
   10 hour rate (0.258A, 10.5V) 2.6Ah
   5 hour rate (0.48A, 10.5V) 2.21Ah
   1C (2.6A, 9.6V) 1.473Ah
   3C (7.8A, 9.60V) 1.04Ah
   
Internal Resistance  
   at 1Khz 22mΩ
   
Maximum Discharge Current (5 sec.) 39A
Charging Methods at 25ºC (77ºF)  
   Cycle Use
 
      Charging Voltage
14.4 to 15V
      Coefficient -5.0mV/ºC/cell
 
      Maximum Charging Current 0.78A

   Standby Use
 
      Float Charging Voltage 13.5 to 13.8V
      Coefficient -3.0mV/ºC/cell  
   
Operating Temperature Range  
      Charge -15°C(5°F) to 40°C(104°F)
      Discharge -15°C(5°F) to 50°C(122°F)
      Storage -15°C(5°F) to 40°C(104°F)
   
Charge Retention (Shelf Life) at 20ºC (68ºF)  
   1 Month
92%
   3 Month
90%
   6 Month 80%
   
Case Material
ABS UL94 HB
 
 
Discharge Rates in Watts to Various End Voltages at 25°C (77°F)
 
Discharge Rates in Amperes to Various End Voltages at 25ºC (77ºF)

*(Note) The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values.
 
Battery Construction
Component Positive Plate Negative Plate Container Cover Safety Valve Terminal Separator Electrolyte
Raw Material Lead Dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric Acid
 
Effect of Temperature on Capacity 25°C(77°C)   Capacity Retention Characteristic
 

Trickle (or float) Service Life
 
Cycle Service Life
 
 

 

Contact us at sales@upsbatterycenter.ca or call us at 416-848-7755